16. INDEXER POSITIONING OPERATION 
 
Code No. 
Item 
Writing data (RWwn 3) contents 
(Programmable controller   Servo amplifier) 
8701h 
to 
87FFh 
Acceleration time constant data RAM 
command of point table 
Writes the acceleration time constants of point 
table No.1 to 255 to RAM. These values are 
cleared when power is switched off. 
The decimal value converted from the 2 lower 
digits of the code No. corresponds to the point 
table No. 
Convert the values into hexadecimal before setting. 
8801h 
to 
88FFh 
Deceleration time constant data RAM 
command of point table 
Writes the deceleration time constants of 
point table No.1 to 255 to RAM. These values 
are cleared when power is switched off. 
The decimal value converted from the 2 lower 
digits of the code No. corresponds to the point 
table No. 
Convert the values into hexadecimal before setting. 
8D01h 
to 
8DFFh 
Servo motor speed data EEP-ROM command 
of point table 
Writes the servo motor speeds of point table 
No.1 to 255 to EEP-ROM. Written to EEP-
ROM, these values are held if power is 
switched off. 
The decimal value converted from the 2 lower 
digits of the code No. corresponds to the point 
table No. 
Convert the values into hexadecimal before setting. 
8E01h 
to 
8EFFh 
Acceleration time constant data EEP-ROM 
command of point table 
Writes the acceleration time constants of point 
table No.1 to 255 to EEP-ROM. Written to 
EEP-ROM, these values are held if power is 
switched off. 
The decimal value converted from the 2 lower 
digits of the code No. corresponds to the point 
table No. 
Convert the values into hexadecimal before setting. 
8F01h 
to 
8FFFh 
Deceleration time constant data EEP-ROM 
command of point table 
Writes the deceleration time constants of 
point table No.1 to 255 to EEP-ROM. Written 
to EEP-ROM, these values are held if power 
is switched off. 
The decimal value converted from the 2 lower 
digits of the code No. corresponds to the point 
table No. 
Convert the values into hexadecimal before setting.