8.11
Action and Handling of Errors
8.11.1
Error code list
This section describes the descriptions and corrective actions for the errors detected by 
the QD64D2.
Table 8.19 Error code list
Error 
code
Description
Action
Operation at error
Error channel
Other channels
0
(Normal)
----
----
----
100
[Overflow error]
Perform the preset.
(Refer to Section 5.4.)
The linear counter 
function stops 
counting.
The error does 
not affect other 
channels.
The present value (Un\G12 and 13) exceeded the 
following range. 
-2147483648 to 2147483647
(Only for the linear counter function)
20m
[Continuous comparison No.m start point setting error]
Set a value from 1 to 16.
The continuous 
comparison cannot 
be started. (The 
error does not 
affect the other 
continuous 
comparison 
number.)
The continuous comparison No.m start point setting 
(Un\G50 and 100) is set to other than 1 to 16.
"m" indicates the continuous comparison number 
where the error occurred. 
21m
[Continuous comparison No.m repeat point setting 
error]
Set a value from 1 to 16.
The continuous comparison No.m repeat point setting 
(Un\G51 and 101) is set to other than 1 to 16. 
"m" indicates the continuous comparison number 
where the error occurred.
22m
[Continuous comparison No.m ON time setting error]
Set a value from 1 to 10.
The continuous comparison No.m ON time setting 
(Un\G52 and 102) is set to other than 1 to 10. 
"m" indicates the continuous comparison number 
where the error occurred.
300
[Count enable execution not possible error]
Turn OFF the coincidence 
output test command which is 
ON. 
The linear counter 
function and ring 
counter function 
does not start 
counting.
The count enable command (Y06) is turned ON while 
one of the following is ON.
•Coincidence output No.1 test command (Y0B)
•Coincidence output No.2 test command (Y0C)