Справочник Пользователя для Mitsubishi Electronics MDS-R

Скачать
Страница из 362
 
8. Setup 
 
 
 
 
 
8 - 5
 
(2) Electronic gear related parameters 
The setting range of the following parameters, which configure the electronic gears, may be limited 
according to the combination. 
Setting electronic gear related parameters 
No. Abbrev. Parameter 
name 
Explanation 
Setting 
range (Unit)
SV001 PC1* 
Motor side gear 
ratio 
1 to 32767
SV002 PC2* 
Machine side gear 
ratio 
Set the motor side and machine side gear ratio. 
For the rotary axis, set the total deceleration (acceleration) ratio. 
Even if the gear ratio is within the setting range, the electronic gears may 
overflow and causes initial parameter error (servo alarm No. 37). 
1 to 32767
SV018 
PIT* 
Ball screw pitch 
Set the ball screw pitch. Set to "360" for the rotary axis. 
1 to 32767
(mm/rev)
In the case of the semi-closed loop control 
Set the same value as SV020 (RNG2).     
(Refer to the explanation of SV020.) 
1 to 9999
(kp/rev) 
In the case of the full-closed loop control 
This is available for the relative position rectangular wave output 
specification linear scale.
 
Set the number of pulses per ball screw pitch. 
 
Detector model name
Resolution 
SV019 setting
 
 
 
Relative position rectangular 
wave output scale 
Refer to detector 
specification manual. 
SV018 (PIT)(mm)/ 
Resolution (µm) 
 
SV019 RNG1* 
Position detector 
resolution 
 
1 to 9999
(kp/PIT) 
Set the number of pulses per one revolution of the motor side detector. 
 
Motor type 
SV020 setting 
 
HF□□-A42 100 
 
 
HF□□-A47 100 
 
SV020 RNG2* 
Speed detector 
resolution 
 
1 to 9999
(kp/rev) 
 
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again. 
 
 
(3) Detector type related parameters 
(a) For semi-closed loop control 
Set the following parameter as below when controlling by using only detector of motor. 
Setting for semi-closed loop control 
No. Abbrev. Parameter 
name 
Explanation 
 
bit 
Explanation 
Set the detector type. 
Set the position detector type for "pen", and the speed detector type 
for "ent". 
ent
In the case of the semi-closed loop control, set the same value for 
"pen" and "ent". 
Detector model name 
pen setting ent setting 
 
A42, A47 
 
D  
pen
 
 
 
 
 
 
SV025 MTYP* Motor/detector 
type 
 
 
 
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.