Справочник Пользователя для Mitsubishi Electronics MDS-R

Скачать
Страница из 362
 
8. Setup 
 
 
 
 
 
8 - 7
 
(4) Setting of regenerative resistor type 
Set the following parameter according to the connected regenerative resistor unit. 
 
No. Abbrev. Parameter 
name 
Explanation 
 
  F E
D
C
B
A
9
8
7
6
5 4 3 2 1
0
 
 1 
rtyp 
emgx 0 
 
 
 bit 
Explanation 
 
 
Set the regenerative resistor type. 
 
 9 
Setting
Details 
  
 A 
rtyp
0 to 1
Setting prohibited 
 
 
 B 
2  GZG200W26OHMJ 
  
  
3 GZG300W20OHMJ 
 
 
  
MR-RB32 or GZG200W120OHMJ 3 units connected 
in parallel 
 
 
  
MR-RB30 or GZG200W39OHMJ 3 units connected in 
parallel 
 
 
  
MR-RB50 or GZG300W39OHMJ 3 units connected in 
parallel 
 
 
  
MR-RB31 or GZG200W20OHMJ 3 units connected in 
parallel 
 
 
  
MR-RB51 or GZG300W20OHMJ 3 units connected in 
parallel 
 
 
  
MR-RB65 or GRZG400-2OHMJ 4 units connected in 
serial 
 
 
  
A GZG80W26OHMJ 
 
 
  
B GZG400W13OHMJ 
 
 
  
C GZG400W8OHMJ 
 
 
 
 
D to F
Setting prohibited 
 
 
 
 
 
 
SV036 PTYP* 
Regenerative 
resistor type 
 
 
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again. 
 
 
 
If the emergency stop state is displayed on the drive unit's LED, the system has started up normally. 
 
 
 
 
 
OFF 
F1 
E7 
F1 
E7 
 
F + axis No. 
F + axis No.
Emergency 
stop 
Emergency 
stop 
 
 
Normal LED display at NC power ON (1st axis) 
 
 
 
CAUTION
  Always input emergency stop when starting up the servo system.