Справочник Пользователя для Mitsubishi Electronics MDS-R

Скачать
Страница из 362
 
9. Adjustment 
 
 
 
 
 
9 - 5
 
A42 
 
A47
 
Motor unit 
Motor unit 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
<When machine resonance does not occur at the standard VGN1>  
Set the standard VGN1. Use the standard value if no problem (such as machine resonance) occurs. If 
sufficient cutting precision cannot be obtained at the standard VGN1, VGN1 can be raised above the 
standard value as long as a 70 percent margin in respect to the machine resonance occurrence limit is 
maintained. The cutting accuracy can also be improved by adjusting with the disturbance observer. 
<When machine resonance occurs at the standard VGN1> 
Machine resonance is occurring if the shaft makes abnormal sounds when operating or stopping, 
and a fine vibration can be felt when the machine is touched while stopped. Machine resonance 
occurs because the servo control responsiveness includes the machine resonance points. (Speed 
control resonance points occur, for example, at parts close to the motor such as ball screws.) 
Machine resonance can be suppressed by lowering VGN1 and the servo control responsiveness, 
but the cutting precision and cycle time are sacrificed. Thus, set a vibration suppression filter and 
suppress the machine resonance (Refer to section "9-3-2 Vibration suppression measures"), and 
set a value as close as possible to the standard VGN1. If the machine resonance cannot be 
sufficiently eliminated even by using a vibration suppression filter, then lower the VGN1.  
No. 
Abbrev. 
Parameter name 
Explanation 
Setting range
SV005 
VGN1 
Speed loop gain 1 
Set the speed loop gain. Set this according to the load inertia size. 
The higher the setting value is, the more accurate the control will be, 
however, vibration tends to occur. If vibration occurs, adjust by lowering 
by 20 to 30%. The value should be determined to be 70 to 80% of the 
value at the time when the vibration stops. 
1 to 999 
 
 
 
POINT
 
The final VGN1 setting value is 70 to 80% of the maximum value at which the 
machine does not resonate. 
Suppressing the resonance with the vibration suppression function and increasing 
the VGN1 setting is effective for adjusting the servo later. 
 
Load inertia scale (%) 
100
200
0
500
250 
400
300
100
200
400 600
300 500
HF353
HF203 
HF53, 103, 153
Load inertia scale (%) 
Standard 
VGN1 
50
 
100
 
0
 
200
 
150
 
100
 
200
400
600
300 500
HF74 
HF44