Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
3.  Tool Offset (L system) 
3.4  Tool Life Management I 
 
 
 
I-98 
Refer to "3 (II). Tool Offset (M system)" for M system.
3.4  Tool Life Management I (#1096 T_L type is 1) 
 
The TOOL LIFE DATA screen will appear when the menu key 
 
 
LIFE 
 is pressed.  
 
 
T-OFSET
T-DATA
NOSE-R 
LIFE 
MENU 
  [TOOL LIFE DATA] 
TOOL 
4.1/4
 
 [TIME] 
[COUNT] 
[STATUS]
  # 
USED MAX 
USED MAX 
  1 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
  2 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
  3 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
  4 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
  5 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
  6 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
  7 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
  8 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
  9 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
 10 
0: 0: 0/ 0: 0 
0/  0 
0: 0 
    # ( )    (    :    :    /    :    ) 
(    /      )      (    :      ) 
 
 
Tool life management is valid when parameter #1103 T_Life is set to 1. Tool life management is then carried 
out according to the tool usage time or the No. of times the tool is used (also called count). When the tool 
usage time reaches the service life time, or when the tool count exceeds the service life count, a tool life 
expiration signal (X20E) is output to the user PLC and the tool No. (#) is highlighted on the TOOL LIFE 
DATA screen.  
Tool life management is possible for up to 80 tools (tool Nos. 1 to 80).  
This function is useful for setting tool abrasion and wear data, and for knowing when to replace tools with 
new ones, etc.  
 
Item Details 
Setting 
range 
USED  The cumulative time the tool is used. 
This timer value is incremented during 
cutting. 
0 : 0 to 99 : 59 
(h: min) 
TIME 
MAX 
The tool service lifetime setting. 
Set the max. time the tool can be used. 
Seconds are discarded. 
0 : 0 to 99 : 59 
(h: min) 
(0 : 0 = no warning given)
USED  The cumulative count the tool is used.  
The counter value is incremented each 
time the tool is used. 
0 to 9999 (times) 
COUNT 
MAX 
The tool service life count. 
Set the max. count the tool can be 
used.  
0 to 9999 (times) 
(0 : 0 = no warning given)
Left 
side 
The tool life management status is 
indicated. 
0: Not used 
1: Current tool (tool being used) 
2: Service lifetime (service life count) is 
 exceeded. 
0 to 2 
STATUS 
Right 
side 
(Machine maker free area) 
0 to 99