3.  Tool Offset (L system) 
3.4  Tool Life Management I 
 
 
 
I-100 
Refer to "3 (II). Tool Offset (M system)" for M system.
3.4.3  Setting Tool Life Management Data 
 
(1)  To set tool life management data, set the tool No. in # (  ). Then set the tool service lifetime and service 
life count data in the corresponding setting areas, and press the 
 
 
INPUT
 key.  
(2)  The operations in (1) update the tool life management data display, increment the tool No. in # (  ) by 1, 
and deletes the service lifetime (life count) data in (     ). 
(3)  If a tool No. and tool life management data is set for a tool No. other than the ones displayed, the screen 
will change to one corresponding to the set tool No. when the 
 
 
INPUT
 key is pressed once. The tool life 
management data can be set by pressing the 
 
 
INPUT
 twice. 
(4)  The tool No. that appears in # (  ) can be continually incremented or decremented by pressing the 
 
 
 
 
and 
 
 
 
 keys. 
 
 
3.4.4  Erasing Tool Life Management Data in Display Screen Units 
 
Ten sets of tool life management data appear in one screen. All the displayed tool life management data 
(time-used, time-max, count-used, count-max) can be set to 0 by pressing the 
 
 
SHIFT 
 key, and then pressing 
the 
   
C.B 
CAN 
 key and 
 
 
INPUT 
 key.  
 
(Note) If any other key has been pressed before the 
 
 
INPUT
 key is pressed, the tool life management data 
will not be erased. 
 
 
3.4.5  Precautions 
 
(1)  The cumulative time (count) is incremented, even if the service lifetime (service count) is set to "0". Note 
that a warning (TOOL LIFE EXPIRATION: X20E) is not output.  
(2)  For tool life management by time, a warning will not be output to the user PLC if the usage time reaches 
the service lifetime during cutting. Instead, the warning will be output when the next tool selection 
command is issued. During that interval, the usage time will continue to increment.  
(3)  When there are 20 offset pairs, the No. of tools whose lifetime can be managed is 20. 
(4)  The TOOL LIFE screen cannot be selected in systems without the tool life management function. If the 
tool life management menu key is pressed, alarm "E06 NO SPEC" will occur and the screen will not 
change.  
(5)  If a tool selection (T) command is carried out during cutting feed modal, the count will be incremented at 
that time.