Справочник Пользователя для Mitsubishi Electronics 60/60S
4. Parameters (User)
4.2 Machining Parameters
I-156
# Item
Contents
Setup
range
(unit)
8205 OT-CHECK-P
This sets the coordinates of the (+) direction in the
moveable range of the stored stroke limit II or the
upper limit coordinates of the prohibited range of
stored stroke limit IIB.
moveable range of the stored stroke limit II or the
upper limit coordinates of the prohibited range of
stored stroke limit IIB.
±99999.999 (mm)
8206 TOOL CHG. P
Set the coordinates of the tool change position for
G30. n (tool change position return).
Set with coordinates in the basic machine
coordinate system.
G30. n (tool change position return).
Set with coordinates in the basic machine
coordinate system.
±99999.999 (mm)
8207 G76/87 IGNR
(For M system only)
Select the shift operation at G76 (fine boring) and
G87 (back boring).
G87 (back boring).
0: Shift effective
1: No shift
1: No shift
8208 G76/87 (–)
(For M system only)
Specifies the shift direction at G76 and G87.
0: Shift to (+)
direction
1: Shift to (–)
direction
8209 G60 SHIFT
(For M system only)
Set the last positioning direction and distance for a
G60 (uni-directional positioning) command.
G60 (uni-directional positioning) command.
±99999.999 (mm)
8210 OT INSIDE
The stored stoke limit function to be set in #8204
and #8205 prevents the machine from moving to the
inside or outside of the specified range.
and #8205 prevents the machine from moving to the
inside or outside of the specified range.
0: Inhibits outside area
(select stored stroke limit II.)
1: Inhibits inside area
(select stored stroke limit II B.)
0/1
8211 MIRR. IMAGE
Enable or disable the parameter mirror image
function.
function.
0: Disable
1: Enable
1: Enable