Справочник Пользователя для Mitsubishi Electronics 60/60S
4. Parameters (User)
4.3 I/O Parameters
I-163
# Item
Contents
Setup
range
(unit)
9108 HAND SHAKE
Specify the transmission control method.
The method will be no procedure if a value except 1
to 3 is set.
The method will be no procedure if a value except 1
to 3 is set.
1: RTS/CTS method
2: No procedure (No
2: No procedure (No
handshaking)
3: DC code method
9109 DC CODE PARITY
Specify the DC code when the DC code method is
selected.
selected.
0: No parity to DC
code (DC3 =
13H)
13H)
1: DC code with
parity (DC3 =
93H)
93H)
9111 DC2/DC4 OUTPUT
Specify the DC code handling when outputting data
to the output device.
to the output device.
DC2 / DC4
0: None / None
1: Yes / None
2: None / Yes
3: Yes / Yes
0: None / None
1: Yes / None
2: None / Yes
3: Yes / Yes
9112 CR OUTPUT
Specify whether to insert the <CR> code just before
the EOB (L/F) code during output.
the EOB (L/F) code during output.
0: Do not add
1: Add
1: Add
9113 EIA OUTPUT
In data output mode, select the ISO or EIA code for
data output.
In data input mode, the ISO and EIA codes are
identified automatically.
data output.
In data input mode, the ISO and EIA codes are
identified automatically.
0: ISO code output
1: EIA code output
1: EIA code output
9114 FEED CHR.
Specify the length of the tape feed to be output at
the start and end of the data during tape output.
the start and end of the data during tape output.
0 to 999 (characters)
9115 PARITY V
Specify whether to check the parity of the No. of
characters in block during data input.
The No. of characters is factory-set so that the
check is valid at all times.
characters in block during data input.
The No. of characters is factory-set so that the
check is valid at all times.
0: Do not perform
parity V check
1: Perform parity V
check
9116 TIME-OUT
Set the time out time to detect an interruption in
communication.
Time out check will not be executed when set to 0 to
30 seconds.
communication.
Time out check will not be executed when set to 0 to
30 seconds.
0 to 30 (s)
9117 DR OFF
Specify whether to check the DR data at the data
input/output.
input/output.
0: DR valid
1: DR invalid
1: DR invalid
9118 DATA ASC II
0: Output in ISO/EIA code (Depends on whether
#9113, #9213, #9313, #9413, or #9513 EIA
output parameter is set up)
output parameter is set up)
1: Output in ASC II code
0/1
9119 INPUT FORM
Specify the mode for input (collation).
0: Standard input (Data from the very first EOB is
0: Standard input (Data from the very first EOB is
handled as significant information.)
1: EOBs following the first EOB of the input data are
skipped until data other than EOB is input.
0/1