Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
6.  Data In/Out 
6.1  DATA INPUT 
 
 
 
I-230 
6.1.4  Inputting Parameter Data 
 
 
Parameter data which has been output by parameter output operation can be input. 
 
The input parameter may go effective immediately after it is input or after the power is once turned OFF/ON. 
(This is the same as when setting from the screen.) After data is input, turn OFF/ON the power. 
 (Note)  Parameter data input operation cannot be made during automatic operation. 
 
 
(1)  Inputting parameter data 
 
Set the data type to parameter. 
#  ( 3 )  DATA  (   ) 
 
 # (  3 ) DATA (      ) 
 
 
 
 
1)  The parameter data input is started. The 
contents of input data and message "DATA IN 
EXECUTION" are displayed. 
Press the 
 
 
INPUT 
 key. 
<INPUT DATA> 
        P5    N1      L···; 
<COMP. DATA> 
 
 
 
 
DATA IN EXECUTION 
# (  3 ) DATA (      ) 
 
 
<INPUT DATA> 
        % 
<COMP. DATA> 
 
 
 
 
DATA IN COMPLETE 
# (    ) DATA (      ) 
2)  When writing is completed, the message "DATA 
IN COMPLETE" will display. 
Turn the power OFF and ON once.
 
 
 
(2)  Input parameter skip operations 
1)  Skipping N No. data not found in the specifications 
 
When "S" is set in the second setting area during data input or compare, and the 
 
 
INPUT 
 key is pressed, 
an error will not occur even if parameter No. (N No.) data not found in the specifications is input. Data 
input and compare of that number will be skipped. 
 
(With normal input and compare, an error will occur if N No. data not found in the specifications is 
input, and data input/compare will be stopped.) 
 
2)  Skipping axis data not found in the specifications 
 
When "S" is set in the second setting area during data input or compare, and the 
 
 
INPUT 
 key is pressed, 
an error will not occur even if data with a different number of axes is input. Axis parameters not found 
in the specifications will be skipped during the input and compare. 
 
3)  Skipping spindle data not found in the specifications 
 
When "S" is set in the second setting area during data input or compare, and the 
 
 
INPUT 
 key is pressed, 
an error will not occur even if data with a different number of spindles is input. Spindle parameters not 
found in the specifications will be skipped during the input and compare.