7.  Diagnosis 
7.1  ALARM MESSAGE 
 
 
 
I-271 
7.1  ALARM MESSAGE 
 
 
When the menu key 
 
 
ALARM 
 is pressed, the ALARM/DIAGN screen is displayed. 
 (1) 
Alarm 
 
 
The code and number or message relating to an operation alarm, program error, MCP alarm, servo 
alarm, or system error are displayed. 
 (2) 
Stop 
code 
 
 
The automatic operation disable state or stop state in automatic operation mode is displayed in code 
and error number. 
 (3) 
Alarm 
message 
 
 
The alarm messages specified by the 
user PLC (built-in) are displayed. 
 (4) 
Operator 
message 
 
 
The operator messages specified by 
the user PLC (built-in) are displayed.
 
 
ALARM 
SERVO SPINDLE
PLC-I/F  MENU 
 <ALARM> 
ALARM/DIAGN 1 
 
M01  OPERATION ERROR  0102 
 
 
 
 <STOP CODE> 
 
 
 <ALARM MESSAGE> 
 
 
 <OPERATOR MESSAGE> 
 
 
 
Refer to the Appendix. List of Alarms for details on the alarms. 
 
When an alarm occurs, the class code will display on all screens. 
 
 
7.1.1  Tracing of Alarm and Stop Codes 
 
 
The alarm data will be stored if an alarm occurs. The stop code displayed at automatic operation stop, etc., 
is also stored. The alarm data and stop codes are stored separately. Up to 24 of each is registered, and the 
last 24 occurrences can be traced. 
 
(1)  Diagnosis of stored alarm and stop code data 
 
 
The data in which the latest 24 alarms or stop codes are stored can be displayed on the alarm diagnosis 
screen and traced. The procedure is shown below. 
 
 
Press either of the following cursor 
keys. 
 
 
 
 
 
 
 
The stored alarm data will display. 
<Alarm>  
 
 
 
Third to previous 
Second to previous 
Previous 
Latest alarm 
<Stop code> 
Latest stop code 
The digit to the right of the <Alarm> display 
shows the occurrence of the data.