6.  Data In/Out 
6.7  Data Protection 
 
 
 
I-269 
 
When an edit lock function is effective, the processing by the machining programs is executed except for 
those I/O functions that are locked. To prevent any negligence of necessary operation, the data protection 
conditions of machining programs are displayed in the DATA IN/OUT screen. Information displayed and the 
screen formats are as follows: 
 
 
• Information displayed 
 Data 
Protection state 
<LOCK> 
 Explanation 
#1 Main program 
        ABC 
Programs A, B, and C are protected 
(Protection KEY 3 OFF) 
 
        BC 
Programs B and C are protected - Edit lock B 
(Protection KEY 3 ON) 
 
        C 
Program C is protected - Edit lock C 
(Protection KEY 3 ON, edit lock B OFF) 
#2 Tool data 
        ON 
Tool data is protected 
(Protection KEY 1 OFF) 
 
        OFF 
(Protection KEY 1 ON) 
#3 Parameter 
        ON 
User parameter data is protected 
(Protection KEY 2 OFF) 
 
        OFF 
(Protection KEY 2 ON) 
 
 
 
DATA INPUT screen
DATA OUTPUT screen 
 
 [DATA INPUT] 
IN/OUT 
 
  
   
<LOCK> 
 #1  MAIN PROGRAM   
 #2  TOOL DATA 
  OFF 
 #3  PARAMETER 
  OFF 
 #5  COMMON VARI    OFF 
 
 
 <INPUT DATA> 
 <COMP. DATA> 
 #10 MODE 
 
 1:IN 
 2:COMP
 #11 
PORT 
NO. 2
 #12  DEVICE 
NO. 1
 (FDD 
: 9600bps) 
  #60 TRACE DATA 
 #99 MAINTENANCE 
 
 [DATA OUTPUT] 
IN/OUT 
   
   
<LOCK> 
 #1  MAIN PROGRAM   
 #2  TOOL DATA 
  OFF 
 #3  PARAMETER 
  OFF 
 #5  COMMON VARI    OFF 
 
 
 <OUTPUT DATA> 
   
 
 #11 
PORT 
NO. 2
 #12 DEVICE 
NO. 1
 (FDD 
: 9600bps) 
  #60 TRACE DATA 
 #99 MAINTENANCE