Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
7.  Diagnosis 
7.4  PLC Interface Diagnosis 
 
 
 
I-284 
7.4  PLC Interface Diagnosis 
 
 
When the menu key 
 
 
PLC-I/F 
 is pressed, the PLC-I/F screen is displayed. 
 
The PLC-I/F screen enables you to set and display input/output signals for PLC (Programmable Logic 
Control) control. 
 
It can be used to check machine sequence operation during PLC development, check input/output data 
between control unit and PLC in operation trouble, and make forcible definition. 
 
 
ALARM SERVO SPINDLE 
PLC-I/F 
MENU 
 [PLC-I/F] 
ALARM/DIAGN 4 
 <SET 
DATA> 
X0008=0001 
Y0015=0000
  
X000A=0001 
D0005=0064
 
 76543210 
HEX   
76543210 
HEX
  X0000 oooooooo 
00 
D0005  oooooooo 
00
  X0008 ooooo1o1 
05 
  o11oo1oo 
64
  X0010 oooooooo 
00 
D0006  1oooooo1 
81
  X0018 o1o1oooo 
50 
  ooooo1oo 
04
  X0020 1o1ooo11 
A3 
D0007  o1oooo1o 
42
  X0028 1ooooo1o 
82 
  1oooo1oo 
84
  X0030 oooooooo 
00 
D0008  oooooo1o 
02
  X0038 oooo11oo 
0C 
  11oooooo 
C0
  DEVICE  DATA 
MODE  DEVICE  DATA  MODE
    (            )    (          )      (    ) 
(            )    (          )      (    ) 
 
 
7.4.1  PLC-I/F Setting and Display 
 
 (1) 
Data 
setting 
area 
 
 
DEVICE (   ) 
 
 
 
Set the device number used with PLC 
(input X
, output Y
, and 
timer T
).
 
 
ALARM SERVO SPINDLE
PLC-I/F 
MENU 
  DEVICE  DATA 
MODE  DEVICE  DATA  MODE
    (            )    (          )      (    ) 
(            )    (          )      (    ) 
For left block 
For right block 
 
 
DATA (   ) 
 
 
 
To forcibly define PLC data, set data corresponding to the setup device number. Set "1" or "0" for bit 
data. Set hexadecimal (HEX) data for byte data. 
 
 
MODE (   ) 
 
 
 
Specify the type of forcible definition. 
1: Single-shot type 
 
 
 
 
 
 
 
 
 
 
    2: 
Modal 
type 
 
 
(2)  Device data display area 
 
 
Data corresponding to the device numbers 
specified in the setting area is displayed. 
 
 
Data is displayed in both binary notation 
and hexadecimal notation. 
 
 
The device numbers can be displayed in 
the left and right blocks separately.
 
 
 
 76543210 
HEX   
76543210 
HEX
  X0000 oooooooo 
00 
D0005  oooooooo 
00
  X0008 ooooo1o1 
05 
  o11oo1oo 
64
  X0010 oooooooo 
00 
D0006  1oooooo1 
81
  X0018 o1o1oooo 
50 
  ooooo1oo 
04
  X0020 1o1ooo11 
A3 
D0007  o1oooo1o 
42
  X0028 1ooooo1o 
82 
  1oooo1oo 
84
  X0030 oooooooo 
00 
D0008  oooooo1o 
02
  X0038 oooo11oo 
0C 
  11oooooo 
C0
Left block 
Right block