7.  Diagnosis 
7.4  PLC Interface Diagnosis 
 
 
 
I-285 
 
(3)  Forcible definition data display 
  
(modal 
type) 
 
 
When forcible definition data and mode are set, 
the device numbers and data are displayed and 
setup data is forcibly defined. 
  
(Note)  To use this function during machine 
running, pay extreme attention to 
sequence operation. 
 
 
(4)  How to read device numbers and 
  
display 
data 
 
 
 
  
76543210  HEX 
 
76543210  HEX 
  X0000  oooooooo 
00 
D0005 oooooooo 
00 
  X0008  ooooo1o1 
05 
 
o11oo1oo 
64 
  X0010  oooooooo 
00 
D0006 1oooooo1 
81 
  X0018  o1o1oooo 
50 
 
ooooo1oo 
04 
  X0020  1o1ooo11 
A3 
D0007 o1oooo1o 
42 
  X0028  1ooooo1o 
82 
 
1oooo1oo 
84 
  X0030  oooooooo 
00 
D0008 oooooo1o 
02 
  X0038  oooo11oo 
0C 
 
11oooooo 
C0 
Device number (bit type) 
X0000 
0 0 0 0 0
0
0
0
 
7 6 5  4  3 2  1 0
X0008 
0 0 0 0 0
1
0
1
X7 X6 X5 X4 X3 X2 X1 X0
X0010 
0 0 0 0 0
0
0
0
XF  XE XD XC XB  XA X9 X8
X17 X16 X15 X14 X13 X12 X11 X10
The device number are assigned 
bitwise. 
State display of signal 
corresponding to each 
device number (1 or 0) 
2-byte data 
corresponding to each 
device number 
Device number (2-byte type) 
D0005 
 
0 0 0 0 0
0
0
0
 
7 6 5  4  3 2  1 0
High-order data
 
0 1 1 0 0
1
0
0
This data indicates decimal number 100.
Low-order data
 
 
 
 
 
 <SET 
DATA> 
X0008=0001 
Y0015=0000
  
X000A=0001 
D0005=0064
Up to four devices that have been 
forcibly defined are displayed.