11.    Visual Analyzer (Waveform display) 
 
 
 
I-372 
 
# Parameter 
Description 
Setting range 
(units) 
data 
Specify data to be sampled. 
  (Servo axis)                            (Spindle) 
1 to 7 
 
 
1: Current FB (%) 
2: Current command (%) 
 
 
3: Position deviation (µm)
4: Position command (µm)
5: Speed FB (r/min) 
1: Motor load (%) 
2: Motor rotation speed 
(speed command value) 
(r/min) 
3: Position deviation (µm)
4: Position command (µm) 
5: Srpm (speed FB) (r/min) 
6: Synchronous error 
width (µm) 
7: Synchronous error 
angle (0.001
°) 
 
 
 
The position command and deviation and synchronous 
tap error width are displayed with an mm unit even when 
inch specifications are set. 
 
4 range 
Specify the size of the vertical axis. 
That is, specify the size of six gradations equivalent to 
the half of the screen. 
(Example 1) In case of current FB 
When #4= 400, the upper half of the screen is 400% 
and the lower half of the screen is –400%. 
(Example 2) In case of position deviation 
When #4= 18000, 18,000
µm (18mm) 
(Example 3) In case of synchronous error width (
µm) 
When #4 = 6000, the scale increment for the vertical 
axis will be 1mm (1000
µm). 
(Example 4) In case of synchronous error angle (0.001
°) 
When #4 = 6000, the scale increment for the vertical 
axis will be 1
°. 
1 to 99999 
level 
Specify the position of level 0 on the vertical axis. 
That is, specify the position of the current and speed 0 
level on the scale. 
In the case of a position command or position deviation, 
the display start position is displayed at the specified 
gradation. 
–6 to 6 
CH2 ax 
Specify the name of the axis to be displayed for CH2. 
No waveform data is displayed if (    ) is left blank. 
Input "/" to erase the displayed waveform. 
Refer to the 
setting range for 
"#2 CH1 axis". 
data 
Refer to "#3 data". (#7 is used for CH2.) 
1 to 7 
range 
Refer to "#4 range". (#8 is used for CH2.) 
1 to 99999 
level 
Refer to "#5 level". (#9 is used for CH2.) 
–6 to 6 
10 
type 
Specify the condition to stop waveform display in 
continuous mode. 
0: Continuous menu OFF 
2: #11 signal ON 
3: #11 signal OFF 
Display will stop when the continuous menu is turned 
OFF regardless of the stopping conditions. 
0, 2, 3 
11 
signal 
Specify the stop signal name in hexadecimal number 
preceded by X or Y. 
X00 to XFF 
Y00 to YFF 
(Note 1)    Only the servo axis name set in "#1022 axname2" can be set in #2 and #6. 
(Note 2)    Only bus connected spindle (#3024 sout=1) can be set in #2 and #6.