Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
11.    Visual Analyzer (Waveform display) 
11.2    Synchronous Tap Error Display 
 
 
I-374 
11.2    Synchronous Tap Error Display 
 
To display the error amount during synchronous tap, set either "6" or "7" in "#3 data" or "#7 data" and 
display the waveform. 
The operation methods and other setting items are the same as the normal waveform display. 
 
 
SINGLE AUTO DISPLAY 
 
 
[VISUAL ANALYZER] 
VISUAL ANALYZER 1. 
 
SYNCH ERR W (mm)    0.006  SYNCH ERR ANG (deg)    2.564 
#1 time 
(1000) 
(ms/div)  
  2 CH1 ax 
( 1) 
 3 data 
(6) 
 4 range  (    6) 
 5 level 
(2) 
  6 CH2 ax 
( 1) 
 7 data 
(7) 
 8 range  ( 6000) 
 9 level 
(-4) 
10 type 
( ) 
11 signal 
(      )  -5 
 
#(  )data(     )( ) 
 
 
 
(Note 1)  With the synchronous tap error display, only the waveform during cutting feed is displayed. 
(Note 2)  Data displayed in "SYNCH ERR W (mm)" and "SYNCH ERR ANG (deg)" on the screen indicates 
the maximum value of the synchronous tap error width obtained from the data displayed as a 
waveform. 
(Note 3)  The "SYNCH ERR W (mm)" is indicated as a value that allows for the gear ratio. 
(Note 4)  The "SYNCH ERR W (mm)" and "SYNCH ERR ANG (deg)" are displayed on the screen only 
when the spindle No. is set in "#2 CH1 axis" (or #6 CH2 axis), and 6 (synchronous tap error 
width) or 7 (synchronous tap error angle) is set in "#3 data" (or #7 data).