Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
6.  Operation Panel Switch Functions 
6.6  Override Cancel 
 
 
 
II-19 
6.6  Override Cancel 
 
 
(1)  When the OVERRIDE CANCEL switch is turned ON, the programmed F command value takes 
precedence over the override value set by using the FEED RATE OVERRIDE switch. 
 
(2)  It is not effective for manual override. 
 
 
6.7  Optional Stop 
 
 
(1)  If M01 is programmed, the machine automatically stops by turning ON the OPTIONAL STOP switch. 
When the switch is OFF, M01 is ignored and the machine does not stop. 
 
(2)  The machine stops after the M01 block is executed. 
 
 
6.8  Optional Block Skip 
 
 
When the OPTIONAL BLOCK SKIP switch is turned ON, a block which begins with a slash ( / ) is skipped; 
when the switch is OFF, the block is executed. This enables the operator to specify whether or not a block 
beginning with a slash ( / ) code is executed. 
 (Example)  To work two parts as illustrated below, if the following program is prepared and work is made by 
turning ON the OPTIONAL BLOCK SKIP switch, part (1) is provided; if work is made by turning 
OFF the switch, part (2) is provided: 
 
 Program 
N1G54 
 
 
      N2G90G81X50. Z-20. R3. F100 ; 
  
 
 
 
/N3X30. 
  
 
 
 
N4X10. 
  
 
 
 
N5G80 
  
 
 
 
M02 
 
 
N4
N4
 
N2
N3
N2
 
Part (1) 
Switch 
ON
 
Part (2) 
Switch OFF