2.  Start up and Adjustment Procedure 
2.3  Turning Power ON, Memory Initialization and Parameter Settings 
 
 
 
III-7 
2.3  Turning Power ON, Memory Initialization and Parameter Settings 
 
 
1)  Turning power ON 
 
 
Confirm the cable connections, etc., before turning the power ON. Especially take care to the power 
system connections. 
 
 
Confirm that the communication terminal screen can be changed over after turning the power ON. 
 
 
2)  Setting of basic specification parameters and initialization of memory 
 
 
(1) Press the [TOOL/PARAM] function selector key on the communication terminal. 
 
 
(2) Press the "Menu" key corresponding to the "Menu" displayed on the bottom of the screen. Change 
the menu display, find the menu display "SETUP", and press that "Menu" key.  
 
 
(3)  The message "Open the setup parameter?" will display on the screen. Press 
 
 
 key, and then 
 
 
INPUT
 
key. 
 
 
(4) The first page of the basic parameters for setup will display, so refer to the section on the 
parameters and set as required. (Parameters #1001 to 1019) 
 
 
(5) Press the "NEXT PAGE" key on the right of the "Menu" keys, and display the second page of the 
basic parameters.  
 
 
(6) Refer to the section on the parameters and set the items as with the first page. (Parameters #1025 
to 1043) 
 
 
(7) Set parameter #1060 
SETUP
 on the second page to "1" (normally it is set to "0"), and perform 
one-touch setup.  
 
 
 
[Procedures for one-touch setup] 
(a) Set "#1060 SETUP" to "1". 
→  The operation message "BASE PARA. 
SET? (Y/N)" will appear. 
 
(b) Set "Y". 
→  The standard parameter will be set. 
The operation message "FORMAT? 
(Y/N)" will appear. 
 
 
(c) Set "Y". 
→  Formatting will start. 
 
 
 
The basic parameters and memory will be initialized. 
 
 
(8) Turn the control unit's input power OFF and ON once. 
 
 
(9) This completes the initialization of the memory. 
 
 
3)  Setting of axis specification parameters 
 
 
(1) Press the [TOOL/PARAM] function selector key on the communication terminal. 
 
 
(2) Press the "Menu" key corresponding to the "Menu" displayed on the bottom of the screen. Change 
the menu display, find the menu display "SETUP", and press that menu key.  
 
 
(3) The message "Display setup parameters?" will display on the screen. Press 
 
 
 key, and then 
 
 
INPUT
 
key. 
 
 
(4) Press the "Axis Parameter" menu key. (Five pages in all.) 
 
 
(5) Refer to "Setup parameters" section and set each item. 
 
 
 
 
 
CAUTION
 
 
  
 
 