Справочник Пользователя для Mitsubishi Electronics 60/60S
5. Stored Stroke Limit
5.2 Stored stroke limit II
III-32
(1) Stored stroke limit II (When prohibited range is on outside)
When used with the stored stroke limit I function, the narrow range designated by the two types becomes
the movement valid range.
the movement valid range.
Range
prohibited with
stored stroke
limit II
Basic machine
coordinate system
coordinate system
Point 1
P
rohi
bi
te
d range
Machine movement
valid range
valid range
– setting value
+ setting
value
P
rohi
bi
ted range
Point 2
Point 3
Point 4
(2) Stored stroke limit IIB (When prohibited range is on inside)
A range except for that of the stored stroke limit I becomes the movement prohibited range.
Range prohibited
with stored stroke
limit IIB
Basic machine
coordinate system
coordinate system
Point 1
P
rohi
bi
te
d range
Machine movement
valid range
valid range
– setting value
+ setting value
P
rohi
bi
te
d range
Point 2
Point 3
Point 4
The following values are set
with the coordinate values in
the basic machine coordinate
system.
with the coordinate values in
the basic machine coordinate
system.
Point 3 and 4:
#8205
#8205
OT-CHECK-P
#8204
OT-CHECK-N
Points 1 and 2 are the
prohibited range set with
stored stroke limit I.
prohibited range set with
stored stroke limit I.