5.  Stored Stroke Limit 
5.2  Stored stroke limit II 
 
 
 
III-32 
(1)  Stored stroke limit II (When prohibited range is on outside) 
When used with the stored stroke limit I function, the narrow range designated by the two types becomes 
the movement valid range. 
 
 
Range 
prohibited with 
stored stroke 
limit II 
Basic machine 
coordinate system
 
Point 1 
P
rohi
bi
te
d range
 
Machine movement 
valid range 
– setting value
+ setting   
value
 
P
rohi
bi
ted range
 
Point 2 
Point 3
Point 4 
 
 
 
(2)  Stored stroke limit IIB (When prohibited range is on inside) 
A range except for that of the stored stroke limit I becomes the movement prohibited range. 
 
 
Range prohibited 
with stored stroke 
limit IIB 
Basic machine 
coordinate system
 
Point 1 
P
rohi
bi
te
d range
 
Machine movement 
valid range
 
– setting value
+ setting value
P
rohi
bi
te
d range
 
Point 2 
Point 3 
Point 4 
 
 
 
The following values are set 
with the coordinate values in 
the basic machine coordinate 
system. 
Point 3 and 4:  
 #8205 
OT-CHECK-P
 
 #8204 
OT-CHECK-N
 
 
Points 1 and 2 are the 
prohibited range set with 
stored stroke limit I.