5.  Stored Stroke Limit 
5.1  Stored stroke limit I 
 
 
 
III-30 
5.1  Stored stroke limit I 
 
This is a stroke limit function used by the machine maker. The boundary is set with the parameters (axis 
specification parameters "#2013 OT–" and "#2014 OT+"). The outside of the set boundary is the prohibited 
range. 
When used with the stored stroke limit II function, the narrow range designated by the two types becomes the 
movement valid range. 
 
Basic machine coordinate system
Point 1 
P
rohi
bi
te
d range
 
Machine movement valid range 
– setting value 
P
rohi
bi
te
d range 
Point 2 
+ setting
value 
 
 
The following values are set 
with the coordinate values in 
the basic machine coordinate 
system. 
Point 1: #2014 OT+ 
Point 2: #2013 OT–