Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
8.  Maintenance Functions 
8.1  Data Input/Output Function 
 
 
 
III-70
 
8.1.4  Parameter Backup 
 
(1) Explanation 
of 
function 
The parameter backup function is used to back up and restore the NC parameters, etc. (including 
options). 
 
(2) Backup 
targets 
The backed up data is the maintenance data output equivalent to ALL1 (table data1) and ALL3 (PLC 
program). Refer to section "8.1.1 Data Format" for details. 
 
(3) Hardware 
configuration 
The memory cassette for maintenance is used to back up and restore the data. 
 
Model 
Compatible memory 
cassette for maintenance 
M64AS HR410/HR450 
M64S HR411/HR451 
M65S/M66S HR415/HR455 
Others No 
function 
 
 
The memory cassette for maintenance is mounted in CBUS#2 on the NC control unit. 
 
 
NC control unit (back side) 
Memory cassette for 
maintenance 
(connect to CBUS#2)
 
 
 
(4) Operation 
methods 
The data is backed up and restored using the BACKUP screen. Refer to section "4.5 BACKUP Screen" in 
"I. OPERATION SECTION" for details on operation. 
 
(Note 1) With the M60S, the NC system cannot start if the maintenance memory cassette is not mounted.