Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
8.  Maintenance Functions 
8.2  Data Sampling 
 
 
 
III-71
 
8.2  Data Sampling 
 
The NC internal data (speed output from NC to amplifier, or feedback data from amplifier, etc.) can be 
sampled and output serially. 
(Setup parameter "#1224 aux08/bit0" must be set to "1" to use this function.) 
 
 
8.2.1  Specifications 
 
• Sampling cycle 
: 3.5ms 
∗ scale 
• Number of sampled axes 
: 1 to 18 axes (Servo axes 
∗ 14 + spindle ∗ 4) 
• Number of sampled points 
: 1 to 8 points 
• Number of sampled data items  : With no memory cassette 
... Max. 3,072 
 
  When using HR412/HR452 (512KB) ... Max. 131,072 
 
  When using HR422/HR462 (1MB)  ... Max. 262,144 
 
  When using HR432/HR472 (2MB)  ... Max. 524,288 
 
(Note 1)  The memory cassette is mounted in CBUS#1. 
(Note 2)  The maximum number of sampled data items is the number of all sampled points. When the data 
to be sampled increases, the number of sampled points will drop per data item. 
 
[Restrictions] 
(1)  When using this function, do not use the input/output functions (PLC, APLC, MELDASNET or 
anshin-net) or the onboard. 
(2)  If the machining program is longer than 1280m or if APLC is added, the memory cassette cannot be 
designated. 
(3)  If a memory cassette is mounted in CBUS#1 for a purpose other than data sampling (to run APLC on 
the SRAM, etc.), the expansion memory cannot be used to sample the data. 
(4)  The data set with this function is not output to the parameters. 
(5)  When the power is turned ON, "#0 Sampling start" will be set to "0" (sampling stop). 
 