Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
2.  Monitor 
2.4  PROGRAM SEARCH 
 
 
 
I-53 
2.4.3  Compare Stop 
 
The single block stop state can be applied at a random block without turning the "SINGLE BLOCK" switch 
ON. 
By using compare stop, the shape machined up to the designated block can be easily compared and 
machining can be resumed. 
 
(1)  Setting compare stop 
 
 
     
 
 
    O ( 1234)    N ( 20) - ( 3 ) COL. ( 1)  TAPE(    )
Designate the program No., 
sequence No. and program No., and 
set 1 in COL. (    ). 
(Example)  To compare stop at   
 01234N20-3 
O ( 1 2 3 4 )    N ( 2 0 ) - ( 3    ) 
COL. ( 1 )  TAPE (  ) 
 
Press the 
 
 
INPUT 
 key. 
The program No. ("MDI" for MDI), 
sequence No., block No., and the 
message "COLL. EXEC" will appear 
at [COLLATION BLOCK]. The setting 
areas will change to blanks. 
To execute compare stop with an 
MDI program, set 0 (zero) for the 
program No. 
  O (    )  N (  ) - (  ) COL. (  ) TAPE (  )
[COLLATION BLOCK]                COLL. EXEC 
O        1234        N      20 - 3
 
Press the "CYCLE START" switch. 
  O (    )  N (  ) - (  ) COL. (  ) TAPE (  )
[COLLATION BLOCK] 
O                        N            -   
1) Operation will start. 
2) When the designated block is 
reached, the signal block stop 
state will be applied after 
executing that block. 
3)  When the single block stop mode 
is established by compare stop, 
the program number, sequence 
number and block number 
appearing in [COLLATE BLOCK] 
as well as the "COLL. EXEC" 
message are cleared.