Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
2.  Monitor 
2.4  PROGRAM SEARCH 
 
 
 
I-54 
(2)  Canceling compare stop 
 
 
Press the 
 
 
INPUT 
 key. 
The program number, sequence 
number and block number settings as 
well as the "COLL. EXEC" message 
are cleared. 
Set 0 in COL. ( ). 
O (      )  N (    ) - (   ) 
COL. ( 0 )  TAPE (  ) 
   
O (        )    N (    ) - (    ) COL. ( 0) TAPE (    )
[COLLATION BLOCK]                COLL. EXEC 
O        1234        N      20 - 3
 
    O (        )    N (    ) - (    ) COL. ( 0) TAPE (    )
[COLLATION BLOCK] 
O                        N            -   
 
 
(3) Precautions 
1)  When there are several identical sequence numbers and block numbers in a program, compare 
stop results after the first corresponding block in the sequence of execution has been executed. 
2)  The compare stop setting is canceled in the following cases. 
 
• When compare stop has been performed 
 
• When "0" has been set in the "COL. ( )" on the SEARCH screen 
 
• When the reset mode has been established 
3)  If only the program number is set, compare stop will take place at the head of the program only 
when there is a program number at the first line. 
4)  When the program and sequence numbers have been set and the block number has not been set, 
the block number is considered to be "0". 
5)  Compare stop cannot be performed for blocks being executed or blocks already read into the 
preread buffer. (Compare stop can be set.) 
6)  Compare stop cannot be canceled if the block in which compare stop is set is being executed or 
has already been read into the preread buffer. (Cancellation of compare stop can be set.) 
7)  Even if a block not included in the execution program is assigned, no check is conducted to verify 
whether it exists in the program. 
8)  Compare stop is not performed in the tapping mode. 
9)  Compare stop is possible in a subprogram, but is not possible in a machine maker macro program. 
10)  If compare stop is set for a fixed cycle block, compare stop will be executed after the positioning 
block is completed. 
11)  Compare stop is possible while the program display is locked (compare stop in an address 9000 
program). 
12)  If compare stop is set for M98 program call, compare stop will be executed at the M98 block. 
13)  When using the 2-part system, the methods for searching the compare stop block can be switched 
with the parameters. 
#1050 MemPrg 
Details 
0, 2, 4, 6 
The compare stop block in the machining program registered in the 
memory common for the systems is searched with the designated 
program No., sequence No. and block No. 
1, 3, 5, 7 
The compare stop block in the machining program registered in the 
memory for the selected system is searched with the designated program 
No., sequence No. and block No.