Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
2.  Monitor 
2.5  Resuming the Program 
 
 
 
I-61 
2.5.2  Restart Search Operations 
 
(1)  Type 1 restart search 
 
a)  Type A (Standard specifications) 
 
 
 Press the 
 
 
INPUT
 key. 
 
M: MODE  <0> MEMORY 
<1> TAPE 
T: TYPE 
<0> UNMODLE 
<1> TYPE 1    <2> TYPE 2
      <3>T-TYP 
  O (   1000)  N (  6) - ( 0) P (      1) T(1) M(0) 
 
M: MODE  <0> MEMORY 
<1> TAPE 
T: TYPE 
<0> UNMODLE 
<1> TYPE 1    <2> TYPE 2
   <3>T-TYP  
       RESEARCH EXECUTION 
    O (      1000)    N (    6) - ( 0) P (            1) T(1) M(0) 
  [PROGRAM RESTART] 
MONITOR 5 .1/ 2 
O    1000   N   5- 0 
<SUB> O                          N        -   
  [RESTART- (G54)]  [RESTART-R] 
  X  -130.000 
X  -150.000 
  Y 
-10.000 
Y  -150.000 
  Z 
0.000 
0.000 
  C 
0.000 
0.000 
 
 
N6 Y-70.; 
N7 X-20.; 
M: MODE  <0> MEMORY 
<1> TAPE 
T: TYPE 
<0> UNMODLE 
<1> TYPE 1 <2> TYPE 2
   <3>T-TYP  
       RESEARCH COMPLETE 
O (       )  N (   ) - (  ) P (      1) T(  ) M(  ) 
 
The "RESEARCH EXECUTION" 
message appears during the search 
and upon its completion the 
"RESEARCH COMPLETE" message 
is displayed. 
Assign the block at which machining
is to restart and proceed with the
type 1 search. 
(Example)  To restart from the   
 
 
01000 N6 block 
O ( 1 0 0 0 )    N ( 6 ) - (      0)
P (      1 ) T ( 1 ) M ( 0 )