2.  Monitor 
2.5  Resuming the Program 
 
 
 
I-59 
(2)  Restart type 2 
When a machining program, which differs from the machining program to be restarted, has been 
operated in the memory or tape mode prior to the restart search of the machining program to be 
restarted, and when the coordinate systems applying during the previous automatic operation and the 
systems applying during machining restart are to be changed. 
The operating sequence for type 2 is the same as that for type 1 although before the restart search all 
the settings of the coordinate systems must be made before the machining program is operated. The 
main program to be restarted must be searched for just before executing restart start. 
 
St a rt
Set by MDI the coordinate systems applying
when the restart program is to start.
Move the axes to their program  restart
p o s it io ns.
W ith tape operation, find the start of the
t a p e .
Search the block from which machining is to
restart using the type 2 method.
(Refer to 2.5.2  Restart Search Operations)
Set the program restart switch (PLC signal) ON.
Move the axes to the restart return positions. (Refer to
2.5.3  Restart Position Return System)
Issue the M, S, T or B manual numerical command.
(Refer  to 2.5.4   Manual Numerical  Commands with
Program Restart)
Set the program restart switch to OFF.
Return to the automatic mode.
Press the cycle start button.
E n d
M a c h i n i n g
p r o g ra m
Machin ing
suspended
Machining
restart
It will not be possible to restart
machining properly when the axxes are
not  located at  the positions  applying to
program   start in cases  where the program
head com m and is an increm ental
com mand or a G92 comm and.
Operations 
                    on 
       PROGRAM 
                     RESTART 
                    screen
           
Upon completion of the restart search, the M, S, T
and B functions, the restart distance to go and the
restart positions will be displayed.
"RP" is displayed when the axes have finished
moving to the restart position and the subsequent
axes, do not move in either the "+" or "-" direction.
Operation of
dif f erent program
Turn ON the power and return all the axes
to their reference points.
Search the head of the program.
For type A, the program No. cannot be omitted.