Справочник Пользователя для Cypress STK14D88

Скачать
Страница из 17
STK14D88
Document Number: 001-52037 Rev. **
Page 7 of 17
AutoStore/POWER UP RECALL
No.
Symbols
Alt.
Parameter
STK14D88
Unit
Notes
Min
Max
22
t
RECALL
Power up RECALL Duration
20
ms
23
t
STORE
t
HLHZ
STORE Cycle Duration
12.5
ms
24
V
SWITCH
Low Voltage Trigger Level
2.65
V
25
V
CCRISE
Vcc Rise Time
150
μs
Figure 8.  AutoStore /POWER UP RECALL 
 Note: Read and Write cycles are ignored during STORE, RECALL, and while V
CC
 is below V
SWITCH
Notes
10. t
HRECALL
 starts from the time V
CC
 rises above V
SWITCH
.
11. If an SRAM WRITE has not taken place since the last nonvolatile cycle, no STORE will take place.
12. Industrial Grade Devices require 15 ms Max.