5.3.5.4.2 
Fault / Status LED 
The following table shows mapping of sensors/faults to the LED state. 
Table 50: Fault / Status LED 
Color 
Condition 
When 
Solid System 
ready 
Green 
Blink 
System ready, but degraded: CPU disabled  
Solid 
Critical failure: critical fan, voltage, or temperature state 
Amber 
Blink 
Non-critical failure: non-critical fan, voltage, or temperature state 
Off 
Solid 
System not ready: POST error / NMI event / CPU or terminator missing 
 
Critical Condition - Any critical or non-recoverable threshold crossing associated with the 
following events: 
• 
Temperature, voltage, or fan critical threshold crossing 
• 
Critical Event Logging errors, including System Memory Uncorrectable ECC errors and 
FSB Bus errors,. 
Non-Critical Condition 
• 
Temperature, voltage, or fan non-critical threshold crossing 
• 
Chassis intrusion 
Degraded Condition 
• 
One or more processors are disabled by Fault Resilient Boot (FRB) 
5.3.5.4.3 
Chassis ID LED 
The Chassis ID LED provides a visual indication of a system being serviced. The state of the 
Chassis ID LED is toggled by the chassis ID button or it can be controlled by the Chassis 
Identify 
command.  
Table 51: Chassis ID LED 
Color 
Condition 
When 
Off Ok 
Blue 
Blink 
Identify button pressed or Chassis Identify command executed 
 
5.3.5.5 
Control Panel Inputs 
The mBMC monitors the control panel switches and other chassis signals. The control panel 
input buttons are momentary contact switches, which are de-bounced by the mBMC processor 
firmware. The de-bounce time is 25 ms.