down, power cycle, and/or reset actions, the actions are performed according to PEF Action 
Priorities.  
Note: An action that has changed from delayed to non-delayed, or an action whose delay time 
has been reduced automatically has higher priority. The mBMC can be configured to log PEF 
actions as SEL events.   
Table 54: PEF Action Priorities 
Action 
Priority 
Delayed  
Type 
Note 
Power-Down 
Yes 
PEF Action  
 
Soft-shutdown 
Yes 
OEM PEF Action 
Not executed if a power-down action was 
also selected 
Power cycle 
Yes 
PEF Action 
Not executed if a power-down action was 
also selected 
Reset 
Yes 
PEF Action 
Not executed if a power-down action was 
also selected 
Diagnostic Interrupt 
No 
PEF Action 
Not executed if a power-down action was 
also selected 
PET Alert 
No 
PEF Action 
When selected, always occurs immediately 
after detection of a critical event.  
Sensor feedback 
No 
OEM PEF Action 
When selected, always occurs immediately 
after detection of a critical event. 
IPMB message event 
No 
OEM PEF Action 
When selected, always occurs immediately 
after detection of a critical event. 
Fault LED action 
No 
OEM PEF Action 
When selected, always occurs immediately 
after detection of a critical event,   and is 
stopped after the de-assertion of all critical 
events that requested LED blinking. 
Identification LED action 
10 
No 
OEM PEF Action 
When selected, always occurs immediately 
after detection of a critical event. 
 
5.3.18.2 
Alert over LAN 
LAN alerts are sent as SNMP traps in ASF formatted Platform Event Traps (PET) to a specified 
alert destination. The Alert over LAN feature is used to send either PET alerts or directed events 
to a remote system management application, regardless of the state of the host’s operating 
system.  
LAN alerts may be sent over any of the LAN channels supported by a platform. LAN alerts can 
be used by PEF to send out alerts to selected destination whenever an event matches an event 
filter table entry. For more information on LAN alerts, see the IPMI specifications v1.5 
5.3.19 
mBMC Sensor Support 
The following tables are for the built-in and the external sensors for the platform. There is a 
management controller locator record as a built-in SDR besides the given below.