Error Code 
Error Message 
Response 
8130 
Processor 01 disabled 
Warning 
8131 
Processor 02 disabled 
Warning 
8140 
Processor 01 failed FRB-3 timer 
Warning 
8141 
Processor 02 failed FRB-3 timer 
Warning 
8150 
Processor 01 failed initialization on last boot. 
Warning 
8151 
Processor 02 failed initialization on last boot. 
Warning 
8160 
Processor 01 unable to apply BIOS update 
Pause 
8161 
Processor 02 unable to apply BIOS update 
Pause 
8170 
Processor 01 failed BIST 
Pause 
8171 
Processor 02 failed BIST 
Pause 
8180 
BIOS does not support current stepping for Processor 1 
Pause 
8181 
BIOS does not support current stepping for Processor 2 
Pause 
8190 
Watchdog timer failed on last boot 
Warning 
8198 
OS boot watchdog timer failure 
Pause 
8300 
BaseBoard Management Controller failed Self Test 
Pause 
8301 
Not enough space in Runtime area!!. SMBIOS data will not be available. 
Pause 
8305 
Primary Hot swap Controller failed to function 
Pause 
84F1 
BIST failed for all available processors 
Halt 
84F2 
BaseBoard Management Controller failed to respond 
Pause 
84F3 
BaseBoard Management Controller in Update Mode 
Pause 
84F4 
Sensor Data Record Empty 
Pause 
84FF 
System Event Log Full 
Warning 
8500 
Bad or missing memory in slot 3A 
Pause 
8501 
Bad or missing memory in slot 2A 
Pause 
8502 
Bad or missing memory in slot 1A 
Pause 
8504 
Bad or missing memory in slot 3B 
Pause 
8505 
Bad or missing memory in slot 2B 
Pause 
8506 
Bad or missing memory in slot 1B 
Pause 
8600 
Primary & Secondary BIOS ID's don't match. 
Pause 
8601 
Override Jumper is set to force boot from lower bank of flash ROM. 
Pause 
8602 
WatchDog Timer Expired(Secondary BIOS maybe bad!). 
Pause 
8603 
Secondary BIOS CheckSum fail. 
Pause 
 
The following table indicates error codes that are sent to the Management Module for error 
logging as a BMC pass-through command. All commands are of “Error” type. The syntax of 
error logging with the management module and SEL is different. The same error is logged 
differently in the SEL than with the Management Module. 
Table 69: Error Codes Sent to the Management Module 
Error code 
Error messages 
161 
Bad CMOS Battery 
301  
Keyboard failure 
102 
System Board failure ( Timer tick 2 test failure) 
106 
Diskette Controller Failure 
604 
Diskette Drive ? failure 
163 
Time of the day not set 
01298000 
The BIOS does not support the current stepping of Processor P0 
01298001 