Table 71: Troubleshooting BIOS Beep Codes 
Number of Beeps  
Troubleshooting Action  
1, 2 or 3  
Reseat the memory, or replace with known good modules.  
4-7, 9-11  
Fatal error indicating a serious problem with the system. Consult your system manufacturer.  
Before declaring the motherboard beyond all hope, eliminate the possibility of interference by a 
malfunctioning add-in card. Remove all expansion cards except the video adapter.  
If the beep codes are generated even when all other expansion cards are absent, the 
motherboard has a serious problem. Consult your system manufacturer.  
If the beep codes are not generated when all other expansion cards are absent, one of the add-
in cards is causing the malfunction. Insert the cards back into the system one at a time until the 
problem happens again. This will reveal the malfunctioning add-in card.  
8  
If the system video adapter is an add-in card, replace or reseat the video adapter. If the video 
adapter is an integrated part of the system board, the board may be faulty.  
 
6.4.4 
Boot Block Error Beep Codes 
The following table defines beep codes that may occur if a failure occurs while performing a 
BIOS Boot Block Update. 
Table 72:  Boot Block Error Beep Codes 
Number of Beeps 
Description 
Insert diskette in floppy drive A:  
‘AMIBOOT.ROM’ file not found in root directory of diskette in A:  
Base Memory error  
Flash Programming successful  
Floppy read error  
Keyboard controller BAT command failed  
No Flash EPROM detected  
Floppy controller failure  
Boot Block BIOS checksum error  
10 
Flash Erase error  
11 
Flash Program error  
12 
‘AMIBOOT.ROM’ file size error  
13 
BIOS ROM image mismatch (file layout does not match image present in flash device)  
1 long beep 
Insert diskette with AMIBOOT.001 File for Multi-Disk Recovery 
 
6.4.5 
BMC Generated Beep Codes (Professional/Advanced only) 
The Sahalee BMC generates beep codes upon detection of the failure conditions listed in the 
following table. Each digit in the code is represented by a sequence of beeps whose count is 