Intel® Server Board SE7520JR2 
Functional Architecture 
Revision 1.0 
 
 
C78844-002 
31
BSP and starts executing from the reset vector (F000:FFF0h). A processor that does not 
perform the role of BSP is referred to as an application processor (AP). 
The BSP is responsible for executing the BIOS power-on self-test (POST) and preparing the 
machine to boot the operating system. At boot time, the system is in virtual wire mode and the 
BSP alone is programmed to accept local interrupts (INTR driven by programmable interrupt 
controller (PIC) and non-maskable interrupt (NMI)).  
As a part of the boot process, the BSP enables the application processor. When enabled, the  
AP programs its Memory Type Range Registers (MTRRs) to be identical to those of the BSP. 
The AP executes a halt instruction with its local interrupts disabled. If the BSP determines that 
an AP exists that is a lower-featured processor or that has a lower value returned by the CPUID 
function, the BSP switches to the lowest-featured processor in the system. 
3.1.8 
CPU Thermal Sensors 
The CPU temperature will be indirectly measured via thermal diodes. These are monitored by 
the LM93 sensor monitoring device. The mBMC configures the LM93 to monitor these sensors. 
The temperatures are available via mBMC IPMI sensors. 
3.1.9 
Processor Thermal Control Sensor 
The Intel Xeon processors generate a signal to indicate throttling due to a processor over temp 
condition. The mBMC implements an IPMI sensor that provides the percentage of time a 
processor has been throttled over the last 1.46 seconds. Baseboard management forces a 
thermal control condition when reliable system operation requires reduced power consumption.  
3.1.10 
Processor Thermal Trip Shutdown 
If a thermal overload condition exists (thermal trip), the processor outputs a digital signal that is 
monitored by the baseboard management sub-system. A thermal trip is a critical condition and 
indicates that the processor may become damaged if it continues to run. To help protect the 
processor, the management controller automatically powers off the system. In addition the 
System Status LED will change to Amber and the error condition will be logged to the System 
Event Log (SEL). 
If either the Intel Management Module Professional Edition or Advanced Edition is present in the 
system, the Fault LED fro the affected processor will also be illuminated. 
3.1.11 Processor 
IERR 
The IERR signal is asserted by the processor as the result of an internal error. The mBMC 
configures the LM93 device to monitor this signal. When this signal is asserted, the mBMC 
generates a processor IERR event. 
3.2   Intel® E7520 Chipset 
The architecture of the Server Board SE7520JR2 is designed around the Intel E7520 chipset. 
The chipset consists of three components that together are responsible for providing the 
interface between all major sub-systems found on the baseboard, including the processor, 
memory, and I/O sub-systems. These components are: