Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-184
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
Receive FIFO Overflow Error Counter Test (#625)
This test reads and clears the BRI port’s Receive FIFO Overflow error counter 
maintained on the BRI-LINE circuit pack. This counter is incremented by the 
circuit pack when it detects an overflow of its receive buffers. The test passes if 
the value of the counter is 0 (that is, the error is cleared). If the counter is 
non-zero, the test fails, and the value of the counter is displayed in the Error 
Code field.
This error can occur if signaling frames are being received from the Packet Bus 
at a rate sufficient to overflow the receive buffers on the circuit pack for a port OR 
if a hardware fault is causing the receive buffers not to be emptied properly by 
the circuit pack. This test is useful for verifying the repair of the problem.
Table 10-61.
TEST #625 Receive FIFO Overflow Error 
Counter Test 
Error 
Code
Test 
Result
Description/ Recommendation
2000
ABORT
Response to the test was not received from the circuit 
pack within the allowable time period.
1. If the test aborts repeatedly a maximum of five times, 
reset the circuit pack via the 
busyout board PCSS
 
and 
reset board PCSS
 commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal System Error.
2100
ABORT
Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to fail, escalate the problem.
value
FAIL
The BRI-LINE circuit pack is still detecting errors of this 
type. The Error Code field contains the value of this 
counter.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to fail, run the Long Test 
Sequence and pay particular attention to the Loop 
Around Tests (#618 and #619). See the repair 
procedures for the executed test if it fails. Otherwise, 
go to the next step.
3. Replace the circuit pack.
Continued on next page