Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-185
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
Clear Error Counters Test (#270)
This test is not an actual test in the strict sense of the word. There are various 
error counters associated with each 
BRI-PORT/ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT. This test clears those 
counters and triggers the auditing of Terminal Endpoint Identifier (TEI) values 
and layer 3 reinitialization. This test is used only to send messages to the 
BRI-PORT/ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT and, therefore, should 
neither abort nor fail.
PASS
The Receive FIFO Overflow error counter was read 
correctly and has a value of 0.
Table 10-62.
TEST #270 Clear Error Counters 
Error 
Code
Test 
Result
Description/ Recommendation
Any
ABORT
This test should never abort.
Any
FAIL
This test should never fail.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS
The message to clear the error counters of the 
BRI-Port/ABRI-Port/ATT-PORT/LGATE-PT/ATTE-PT has 
been sent.
Continued on next page
Table 10-61.
TEST #625 Receive FIFO Overflow Error 
Counter Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page