Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-186
BRI-SET, ASAI-ADJ, BRI-DAT 
10
BRI-SET, ASAI-ADJ, BRI-DAT
!
CAUTION:
A detailed flowchart for isolating and resolving Packet Bus faults is included 
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit 
pack is located (01, 02, ..., etc.); and pp is the 2-digit port number (for example, 01). The 
alternate name field contains the extension of the endpoint. This field is used to distinguish 
between endpoints on the same port.
2.
The alarm level for ASAI and AT&T adjuncts may be administered using the 
set 
options
 command. The alarm level can be set independently for Off-Board and 
On-Board alarms to WARNING, MINOR, or MAJOR for all ASAI and AT&T adjuncts 
in the system.
3.
Alarming for an ASAI and AT&T adjuncts is disabled if the adjunct asks the switch 
to suspend maintenance. When this occurs, an error and a WARNING alarm are 
logged against the endpoint. Busying out and releasing the ASAI station or ADJLK 
station will clear the alarm.
MO Name As 
It Appears in 
Alarm Log
Alarm Level
Initial System 
Technician 
Command to Run
1
Full Name of MO
BRI-SET
WARNING
2
test station extension 
l, test data-module 
extension
ISDN-BRI Set
ASAI-ADJ
MAJOR
2
test station extension
ASAI-Adjunct
ASAI-ADJ
MAJOR
2
test data-module 
extension
ASAI-Adjunct
ASAI-ADJ
WARNING
3
test data-module 
extension
ASAI-Adjunct
ATT-ADJ
MAJOR
2
test station extension
AT&T-Adjunct
ATT-ADJ
MAJOR
2
test station extension
AT&T-Adjunct
ATT-ADJ
WARNING
3
test station extension
AT&T-Adjunct
LGATE-AJ
MAJOR
2
test station extension
Ethernet ASAI-Adjunct
LGATE-AJ
MAJOR
2
test station extension
Ethernet ASAI-Adjunct
LGATE-AJ
WARNING
3
test station extension
Ethernet ASAI-Adjunct
ATTE-AJ
MAJOR
2
test station extension
Ethernet AT&T-Adjunct
ATTE-AJ
MAJOR
2
test station extension
Ethernet AT&T-Adjunct
ATTE-AJ
WARNING
3
test station extension
Ethernet AT&T-Adjunct
BRI-DAT
test data-module