Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1156
PR-MAINT (Maintenance Processor)
10
MTP Reset Test (#101)
This test is destructive.
The test resets the Maintenance/Tape Processor. The
destructive nature of this test causes the following:
■
Administration terminal to log off
■
CDR port to terminate data transmission
■
Any current tape access to terminate and also to tear down any remote
access INADS connection
access INADS connection
Table 10-345.
TEST #101 MTP Reset Test
Error
Code
Code
Test
Result
Description/ Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
error codes.
10102
ABORT
System software resources required for this test are not available.
10104
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
10105
FAIL
The MTP did not respond to being reset.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit pack.
10106
FAIL
The Maintenance/Tape Processor was reset, but it responded with a NOT
PASS status, indicating that it did not pass initialization correctly. The MTP
is not functioning correctly. The system should continue to function, but it
will not have the ability to save translation to tape, or to read tape if the
system needs to be rebooted. Environmental monitoring is lost, as is
communication with the Standby Processor.
PASS status, indicating that it did not pass initialization correctly. The MTP
is not functioning correctly. The system should continue to function, but it
will not have the ability to save translation to tape, or to read tape if the
system needs to be rebooted. Environmental monitoring is lost, as is
communication with the Standby Processor.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, replace the Processor circuit pack.
Continued on next page