DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1157
PR-MAINT (Maintenance Processor) 
10
MTP Outpulse Relay Test (#102)
This test is a nondestructive test. The test validates the correct operation of the 
remote access CO trunk used by INADS. The MTP first goes off-hook, then 
on-hook on this trunk. If the loop current is detected, the test passes. This test is 
not allowed if the remote access line is in use.
PASS
The Maintenance/Tape Processor was reset, and it passed initialization 
correctly. The other MTP tests should be examined to verify that the MTP is 
functioning correctly.
1. Enter 
test processor a/b
 and verify that the MTP is functioning 
correctly.
Table 10-346.
TEST #102 MTP Outpulse Relay Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
1018
ABORT
The test has been disabled via administration.
1. To enable the test, issue the 
change system-parameters 
maintenance
 command, and set the test remote access port field to "y." 
(If you have an INADS line, set the field to "y." If you are testing the 
Standby PR-MAINT, a 
refresh spe-standby
 command must be 
successfully executed before you proceed to Step 2.
2. Rerun the test.