10 - 6                                                                                                                                                       10 - 6 
MELSEC-Q
 
10   MAINTENANCE AND INSPECTION 
 
(b) CPU module whose serial number's first 5 digits are "04011" or earlier 
 
Battery life 
SRAM card 
Energization 
Time Ratio 
Guaranteed value 
(MIN) 
Value in actual use 
(TYP) 
After SM51 is energized 
(Guaranteed time after 
alarm occurrence) 
0% 690hr  6336hr 
8hr 
Q2MEM-1MBS 
Manufacturing 
control number 
"
A" 
Q2MEM-2MBS 
100% 11784hr  13872hr 
8hr 
 
1: The energization time ratio denotes the ratio of power-on time in a day (24 hours) . 
(When power is on for 12 hours and off for 12 hours, the energization time ratio is 
50%.) 
2: The manufacturing control number is given on the SRAM card rear label (see 
below). 
 
CAUTION
Do not subject to mechanical shock!
Do not expose to extreme temperrature,
Manufacturing control number
 
 
POINT 
 
Remember that the SRAM card consumes battery power even when the battery is 
connected to the CPU module and the power is turned ON. 
 
If the  special relay SM51 (battery low latch) turns on, immediately replace the battery. 
If an alarm has not yet occurred, it is recommended to replace the battery periodically 
according to the conditions of use.