FortiBridge Version 3.0 Administration Guide
42
09-30000-0163-20061109
Configuring FortiBridge alerts
Configuration and operating procedures
02-01-2005 8:21:27 Local7.Alert 172.20.120.13 date=2005-02-
01 time=15:26:59 device_id= log_id=0100020001 type=event 
subtype=system pri=alert msg="FortiBridge detect FortiGate 
failure: [failed time: Tue Feb  1 15:26:59 2005][failed 
protocol: ftp] [failed FortiGate serial number: 
FGT8002803923050]"
02-01-2005 18:17:17 Local7.Alert 172.20.120.13 date=2005-02-
01 time=15:22:49 device_id= log_id=0100020001 type=event 
subtype=system pri=alert msg="FortiBridge detect FortiGate 
failure: [failed time: Tue Feb  1 15:22:49 2005][failed 
protocol: ping] [failed FortiGate serial number: 
FGT8002803923050]"
02-01-2005 8:13:43 Local7.Alert 172.20.120.13 date=2005-02-
01 time=15:19:15 device_id= log_id=0100020001 type=event 
subtype=system pri=alert msg="FortiBridge detect FortiGate 
failure: [failed time: Tue Feb  1 15:19:15 2005][failed 
protocol: smtp] [failed FortiGate serial number: 
FGT8002803923050]"
To configure FortiBridge syslog
In most cases you should only need to configure the IP address of the syslog 
server to receive FortiBridge syslog messages. See 
 for more FortiBridge syslog options.
1
Log into the CLI.
2
Configure syslog settings. Enter:
config log syslogd setting
set server 172.20.120.11
end
FortiBridge SNMP
If you set the probe action on failure to snmp, you can configure FortiBridge SNMP 
settings so that the FortiBridge unit sends SNMP v1 and v2c compliant traps to 
SNMP v1 and v2c compliant SNMP managers if the FortiBridge unit detects a 
failure. The traps inform the recipient that a FortiGate unit has failed and include 
the protocol for which the failure was detected.
Only the first probe to detect a failure triggers the actions on failure. So, even if 
multiple probes are configured, when a failure is detected, the FortiBridge unit 
sends one v1 SNMP trap and one v2c SNMP trap.
Configure FortiBridge SNMP by adding and configuring an SNMP community. An 
SNMP community is a grouping of equipment for network administration 
purposes. You can add up to three SNMP communities. Each community can 
have a different configuration for SNMP traps. You can add the IP addresses of up 
to 8 SNMP managers to each community.