C H A P T E R   5 :   E T H E R N E T / I P   P R O T O C O L  
5 . 2 . 2  
O n D e m a n d   N o d e   0 1   C o n f i g u r a t i o n   P a g e  
 
The OnDemand Node 01 Configuration Page 
Use this page to modify the settings for Node 01.   
Controller Settings 
5 Select the Controller Type from the drop-down menu. The Controller Type 
(in this case) specifies the type of PLC that will be communicating with the 
HS500E.  
6 Enter the Controller’s IP address. Controller IP address is the IP address 
assigned to the PLC. 
7 Enter the Controller’s Slot Number (0-255). Controller Slot Number 
indicates where in the PLC rack the controller module is installed; normally 
slot 0 for ControlLogix. 
Write Settings 
8 Specify the number of words (between 1 and 100, 0 = disabled) for the Max 
Write Size. The Max Write Size value represents the maximum number of 2-
byte “words” that the HS500E will attempt to write to PLC memory during 
each command-response cycle. Note: the actual data size required on the 
PLC is 3 words larger than the value specified in this field.
 
H S 5 0 0 E   –   O P E R A T O R ’ S   M A N U A L                                          
P / N :   1 7 - 1 3 0 5   R E V 0 2   ( 1 2 - 0 5 )  
P A G E   4 2   O F   8 2