TROUBLESHOOTING
12.3 Error Code List  
12.3.5  Error code list (3000 to 3999)
12
 - 36
9
EM
C AN
D
 L
O
V
O
LT
AG
DI
RE
C
T
IV
E
S
10
LO
A
D
ING A
ND 
INS
TA
LLA
T
ION
11
M
A
INT
E
NANCE
 AND 
IN
SP
ECT
IO
N
12
T
R
O
U
BL
ES
HO
O
T
IN
G
 A
PPE
NDICES
 INDEX
 
 
*1 This applies when the serial number (first five digits) of the MELSECNET/H module is "08102" or later.
*2 This applies when the serial number (first five digits) of the CPU module is "10031" or earlier.
*3 This applies when the serial number (first five digits) of the CPU module is "13042" or later.
Error 
Code
(SD0)
Error Contents and Cause
Corrective Action
Corresponding 
CPU
3000
The PLC parameter settings for timer 
time limit setting, the RUN-PAUSE 
contact,  and number of vacant slots is 
outside the range that can be used by 
the CPU module.
Read the detailed information of the 
error using the GX Developer, check the 
parameter items corresponding to those 
numerical values (parameter numbers), 
and correct when necessary.
QS
3001
The parameter settings are corrupted.
3003
The number of devices set at the PLC 
parameter device settings exceeds the 
possible CPU module range.
Read the detailed information of the 
error using the GX Developer, check the 
parameter items corresponding to those 
numerical values (parameter numbers), 
and correct when necessary.
QS
3004
The parameter file is incorrect.
Alternatively, the contents of the file are 
not parameters.
Check whether the parameter file 
version is
.QPA, and check the file 
contents to be sure they are 
parameters.
QS
3008
The system power is not restarted or 
the CPU module is not reset after 
writing the parameter to the CPU 
module. (When the remote I/O station 
returns while the system power is 
restarted or the CPU module is reset 
after writing the PLC parameter into 
CPU module, this error occurs.)
Restart the power or reset the CPU 
module.
QS
3100
• The number of modules actually 
mounted is different from that is set in 
Network parameter for CC-Link IE 
Field Network.
• The start I/O number of the module 
actually mounted is different from that 
is set in Network parameter for CC-
Link IE Field Network.
• Some data in the parameters are not 
supported.
• Check the setting in Network 
parameter and actual mounting 
status, and if they differ, correct either 
the setting or mounting status so that 
they become the same. If the 
parameter setting is corrected, write 
Network parameter to the CPU 
module.
• If an error occurs even after 
correction, a hardware failure is 
considered. (Please consult your 
local Mitsubishi representative.)
QS