Справочник Пользователя для Mitsubishi Electronics CR751-D

Скачать
Страница из 190
3 Controller
  Dedicated input/output   
3-76
3.5 Dedicated input/output
Show the main function of dedicated input/output in the 
. Refer to attached instruction manual 
"Detailed explanations of functions and operations" in the product for the other functions. Each parameter indi
-
cated with the parameter name is used by designated the signal No., assigned in the order of input signal No. and 
output signal No. 
Table 3-2 : Dedicated input/output list
Parameter 
name
Input
Note1) 
Output
Name
Function
Level
Name
Function
TEACHMD
None
Teaching mode out
-
put signal
Outputs that the teaching mode is 
entered.
ATTOPMD
None
Automatic mode out
-
put signal
Outputs that the automatic mode is 
entered.
ATEXTMD
None
Remote mode output 
signal
Outputs that the remote mode is 
entered.
RCREADY
None
Controller power ON 
complete signal
Outputs that external input signals can 
be received.
AUTOENA
Automatic opera
-
tion enabled input 
signal
Allows automatic operation.
L
Automatic operation 
enabled output signal
Outputs the automatic operation 
enabled state.
START
Start input signal
Starts all slots.
E
Operating output sig
-
nal
Outputs that the slot is operating.
STOP
Stop input signal
Stops all slots.
The input signal No. is fixed to 0.
Note) Use the emergency stop 
input for stop inputs related 
to safety.
L
Wait output signal
Outputs that the slot is temporarily 
stopped.
STOP2
Stop input signal
The program during operation is 
stopped. 
Unlike the STOP parameter, 
change of the signal number is 
possible. 
Notes) Specification is the same as 
the STOP parameter. 
L
Wait output signal
Outputs that the slot is temporarily 
stopped.
Notes) Specification is the same as the 
STOP parameter. 
SLOTINIT
Program reset input 
signal
Resets the wait state.
E
Program selection 
enabled output signal
Outputs that the slot is in the program 
selection enabled state.
ERRRESET Error reset input 
signal
Resets the error state.
E
Error occurring out
-
put signal
Outputs that an error has occurred.
CYCLE
Cycle stop input 
signal
Carries out cycle stop.
E
In cycle stop opera
-
tion output signal
Outputs that the cycle stop is operat
-
ing.
SRVOFF
Servo ON enabled 
input signal
Turns the servo OFF for all mech
-
anisms.
L
Servo ON enabled 
output signal
Outputs servo-on disable status.
 (Echo back)
SRVON
Servo ON input 
signal
Turns the servo ON for all mecha
-
nisms.
E
In servo ON output 
signal
Outputs the servo ON state.
IOENA
Operation rights 
input signal
Requests the operation rights for 
the external signal control.
L
Operation rights out
-
put signal
Outputs the operation rights valid state 
for the external signal control.
MELOCK
Machine lock input 
signal
Sets/resets the machine lock 
state for all mechanisms.
E
In machine lock out
-
put signal
Outputs the machine lock state.
SAFEPOS
Evasion point 
return input signal
Requests the evasion point return 
operation.
E
In evasion point 
return output signal
Outputs that the evasion point return 
is taking place.
OUTRESET General-purpose 
output signal reset
Resets the general-purpose output 
signal.
E
None
EMGERR
None
Emergency stop out
-
put signal
Outputs that an emergency stop has 
occurred.
S1START
  :
S32START
Start input
Starts each slot.
E
In operation output
Outputs the operating state for each 
slot.