GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS 
VULCAN-HART                                                                                                                F-32934 Rev. J (August 2012) 
-9-
 
 
 
When installing a quick disconnect you must also install a means for limiting the 
movement of the fryer.  This device will prevent the gas line or quick disconnect 
from being strained.  The restraining device should be attached to the cutout on the 
back panel.  See illustration for location. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
In Australia, use only the caster supplied by the manufacturer for the fryer 
device.  The fryer must be installed using a hose assembly restraining device to 
limit the movement of the appliance in accordance with AS1869. 
 
 
The fryer must be installed with a connector (not supplied by Vulcan)  
complying with the above codes. 
 
 
The fryer must be installed with restraining means to guard against  
transmission of strain to the connector.  See illustration. 
 
 
The fryer must be installed with the casters provided. 
 
 
If the restraint is ever to be disconnected, first turn the gas supply off. 
 
 
ELECTRICAL CONNECTION 
 
Electrical Grounding Instructions: 
 
 
This appliance is equipped with a three prong (grounding) plug for your protection against 
shock hazard and should be plugged directly into a properly grounded three-prong  
 
receptacle. Do not cut or remove the grounding prong from this plug. Fryer must be 
electrically grounded in accordance with local codes, or in the absence of local codes, with