Справочник Пользователя для Master Bilt TAF-27 ERC2
11
Minimum
Compressor
On Time
Compressor
On Time
Con
Minimum time that
the compressor
remain turned on
remain turned on
Range: from 0 to 15 min
2 min.
Alarm Delay
ALrd
Time delay before
the alarm goes off
after the
temperature fall
off the two alarm
set points
after the
temperature fall
off the two alarm
set points
Range: from 0 to 59 min
30 – for LT
45 – for MT
45 – for MT
Compressor
Run Time
Run Time
CPrn
Time the
compressor runs
between defrosts
between defrosts
12 – for MT
Number of
Defrosts
Defrosts
nodF
Number of defrosts
per day
from 0 to 8 (0 means 1 defrost
every 48 hours)
N/A – for LT
0 – for MT
0 – for MT
Defrost Start
Time
Time
dEF1-8
Start time of each
defrost
N/A
Defrost
Duration
Duration
dEFd
Defrost duration
time (back-up for
defrost
termination
temperature)
defrost
termination
temperature)
Range: from 0 min to 4 hours
35 – for LT
0 – for MT
0 – for MT
Fan Delay
FAnd
Delay time for the
fan after defrost
(back-up for fan
cut-in
temperature)
(back-up for fan
cut-in
temperature)
Range: from 0 to 15 min
2 – for LT
0 – for MT
0 – for MT
Pump Down
Pudn
Pump down duration Range: from 0 to 59 min
0 min.
Drip Time
driP
Drip time duration
Range: from 0 to 59 min
2 – for LT
0 – for MT
0 – for MT
Setpoint
Differential
Differential
diF
°
Cut-in temperature
differential
Note: cut-in is cut-
out plus differential
Note: cut-in is cut-
out plus differential
Range: from 1 to 25
°
10
°
F–for LT
7
o
F – for MT
Temperature
Initiated
Defrost
Initiated
Defrost
tdEF
Temperature that
will initiate a
defrost cycle
defrost cycle
Range: from – 40 to 40
°
F or – 40 to
4
°
C
N/A
Defrost
Termination
Temperature
Termination
Temperature
dEF
°
Temperature in the
evaporator that
will terminate the
defrost cycle
will terminate the
defrost cycle
Range: from 0 to 75
°
F or –18 to
25
°
C
50
°
F
Fan Cut-In
Temperature
Temperature
FAn
°
Temperature in the
evaporator that
will turn the fan
on after defrost
will turn the fan
on after defrost
Range: from – 40 to 60
°
F or – 40 to
23
°
C
30
°
F–for LT
60
o
F–for MT
Low
Temperature
Alarm
Temperature
Alarm
ALLo
Low temperature
setpoint that will
make the alarm go
off and the error
message appear on
the display
make the alarm go
off and the error
message appear on
the display
Range: from – 40 to 83
°
F or – 40 to
23
°
C
-40
°
F–for LT
32
o
F–for MT