Справочник Пользователя для Master Bilt TAF-27 ERC2

Скачать
Страница из 18
 
9
To initiate a Manual Defrost, press and hold the MAN DEF key for 3 seconds. 
 
There are two levels of programming in the ERC 2. The first level of security will enable the user to 
set two parameters: Time-of-day (
CLoC
) and Set point temperature (
SEt
). The other level allows 
access to the other parameters. 
 
 
Three buttons are used for the programming: SET, UP and DOWN 
 
 
Fig. 4 – Display Lay-out 
  
To change time-of-day and set point temperature (First Level) follows these steps: 
 
Step 1 
 
Press and hold set for 5 seconds. The display will show 
CLoC
 
Step 2 
 
Press SET again to change the time-of-day 
Step 3 
 or 
 
Press UP or DOWN until the correct time-of-day is displayed 
Step 4 
 
Press SET to accept the new time 
Step 5 
 
Press DOWN to go to the next parameter – Set point 
Temperature - (cut out) 
Step 6 
 
Press SET to change the set point temperature 
Step 7 
 or 
 
Press UP or DOWN to go to the desired set point. The range is  
– 40 to 60
°
F or –40 to 16
°
C  
Step 8 
 
Press SET to accept the change 
Step 9 
 
Press DOWN to exit the first level of programming 
 
Note 1: During programming, if no button is pushed during 30 seconds, the control will go 
back to the normal operating mode. This is valid for both programming levels. 
 
Note 2: When changing the time, press and hold the MAN DEF button for 3 seconds to 
change the AM/PM mode. 
 
Note 3: Master-Bilt’s Set point Temperature (
Set)
 is set at a recommended –10
°
F at the 
factory for low temperature(LT) and +35
o
F for medium temperature(MT) application.  
  
 
Note 4: If demand defrost (
ddEF
) is used, the minimum number of defrost is 1 per 24 hours.