Operation selection functions 4 (Pr. 800 to Pr. 809)
P
A
RAMETERS
3
3.31 Operation selection functions 4 (Pr. 800 to Pr. 809)
3.31.1 Control selection (Pr. 800, Pr. 451
)
z Select the inverter control system such as speed control, torque control or position control.
z When "9" is set in Pr. 800, speed control test operation can be performed even when the motor is not connected. 
The speed calculation value changes to track the speed command and the transition can be checked with the 
control panel and analog signal output at DA1 and DA2.
3.31.2 Torque characteristic selection (Pr. 801
)
Used to select the control method.
z Setting Pr. 800 (Pr. 451) control system selection enables the following combination using the MC signal 
(mode changing). 
 
Use terminal RT to switch to the second motor control method selection.
Parameter
Name
Factory Setting
Setting Range
800
Control system selection
0
0 to 5, 9, 20
451
Second motor control method selection
9999
20, 9999
Pr. 800 Setting
Control System
Control Method
Remarks
0
Vector control 
with encoder
Speed control
Factory setting
1
Torque control
2
Speed control-torque control switchover
MC ON: Torque control
 
MC OFF: Speed cotrol
3
Position control
4
Speed control-position control switchover MC ON: Position control 
MC OFF: Speed control
5
Position control-torque control switchover MC ON: Torque control 
MC OFF: Position control
9
Vector control test operation
20
V/F control
Speed control
CAUTION
• When supplying power only across R1-S1, E.OC1 (overcurrent at acceleration) occurrs when the start 
signal turns on.
• Since current is not detected and voltage is not output, monitors related to current and voltage such as 
output current and output voltage, etc. and output signals do not function.
• For speed calculation, speed is calculated in consideration of Pr. 880 "load inertia ratio".
 
Related parameters
 
MC signal terminal assignment 
⇒ Set "26" in any of Pr. 180 to Pr. 183 and Pr. 187 (input terminal function selection). (Refer to page 150.)
When using the motor with encoder, you can select the torque characteristic.
Parameter
Name
Factory 
Setting
Setting Range
Dedicated motor 
(SF-V5RU)
Motor with encoder 
(e.g. SF-JR)
801
Torque characteristic selection
1
0
Mitubishi dedicated motor 
torque characteristic
Cyclic operation mode
1
Continuous operation mode
CAUTION
• Whether the motor used is a Mitsubishi dedicated motor or motor with encoder is judged by the 
setting of Pr. 71   "applied motor". Refer to page 111.
• Usually, operate in the continuous operation mode (setting value: 1)
 
Torque at a low speed is not sufficient in the cyclic operation mode (setting value: 0). 
 
Note this when changing the setting.
speed
torque
position
speed
torque
position