AXIS SPECIFICATIONS PARAMETERS 
6.2 
Zero Point Return Parameters 
II - 89 
 
6.2  Zero Point Return Parameters 
After setting up the parameter (PR) listed in the table, turn OFF the NC power.  To validate the parameter, 
turn ON the power again. 
(SETUP PARAM 2. 3/8) 
Items 
Details 
Setting range (unit) 
2025 G28rap  G28 rapid 
traverse rate 
Set up a rapid traverse rate for dog type reference 
point return command. 
1 to 999999 
(mm/min) 
2026 G28crp  G28 approach 
speed 
Set up the speed of approach to the reference point in 
the reference point return command.  This speed is 
attained after the system stops with deceleration by 
dog detection. 
Note)  The G28 approach speed unit is (10°/min) only 
when using the Z-phase type encoder (#1226 
aux10 bit3=1) for the spindle/C-axis reference 
point return type. The same unit is used for 
both the micron and sub-micron specifications. 
1 to 60000 (mm/min)
2027 G28sft 
Reference 
point shift 
distance 
Set up the distance from the electrical zero-point 
detection position to the actual machine reference 
point during reference point return. 
Note)  When #1240 set12 (bit2) is ON, a 
magnification (C: 10-fold) corresponding to the 
input setting unit (#1003 iunit) will be applied 
on the setting value. 
0 to 65535 (µm) 
2028 grmask  Grip mask 
amount 
Set up a distance where the grid point is ignored when 
near-point dog OFF signals are close to that grid point 
during reference point return. 
The grid mask is valid by one grid. 
0 to 65535 (µm) 
Even when the least 
setting increment is 
0.1µm, set up the 
value in units of µm.
 
2029  grspc 
Grid interval 
Set up a detector grid interval. 
Generally, set up the value equal to the ball screw 
pitch.  However, if the detector grid interval is not 
equal to the screw pitch when measured with a linear 
scale, set up the detector grid interval.  
To reduce the grid interval, use its divisors. 
To use 0.001 mm as minimum setup units, set up the 
negative value. 
Example)  Setup value 
→ 1.000 mm (°) 
−1 → 0.001 mm (°) 
Even when the least setting increment is 0.1µm, it will 
be 0.001mm if a negative value is set. 
−32767 to 999 (mm)