6. 
AXIS SPECIFICATIONS PARAMETERS 
6.2 
Zero Point Return Parameters 
II - 91 
 
 (SETUP PARAM 2. 4/8) 
Items 
Details 
Setting range (unit) 
2037 
2038 
2039 
2040 
G53ofs 
#2
_rfp 
#3
_rfp 
#4
_rfp 
Reference 
point #1 to #4 
Set up the position of the first, second, third, and fourth 
reference points from the zero point of the basic 
mechanical coordinates. 
 
Basic mechanical coordinates
M
Reference point #1 
Reference point #2 
Reference point #3
Reference point #4
 
 
±999999.999 (mm)