6. 
AXIS SPECIFICATIONS PARAMETERS 
6.4 
Axis Specifications Parameters 2 
II - 96 
 
 (SETUP PARAM 2. 7/8) 
Items 
Details 
Setting range (unit) 
2073  zrn_dog 
Origin dog  Under the standard specifications, the origin dog signal 
is assigned to a fixed device.  When it is desired to 
assign the origin dog signal to a position other than the 
fixed device, specify the input device in this parameter. 
Note 1:  This parameter is valid when 1 is set in #1226 
aux10 bit 5. 
Note 2:  When this parameter is valid, do not set the 
same device number.  If the same device 
number exists, an emergency stop occurs.  
However, no device number check is performed 
for an axis to which a signal that ignores the 
near-point dog signal (R157) is input. 
00 to FF (HEX) 
2074  H/W_OT+  H/W OT+
Under the standard specifications, the OT (+) signal is 
assigned to a fixed device.  When it is desired to assign 
the OT (+) g signal to a position other than the fixed 
device, specify the input device in this parameter. 
Note 1:  This parameter is valid when 1 is set in #1226 
aux10 bit 5. 
Note 2:  When this parameter is valid, do not set the 
same device number.  If the same device 
number exists, an emergency stop occurs.  
However, no device number check is performed 
for an axis to which a signal that ignores the OT 
signal (R156) is input. 
00 to FF (HEX) 
2075  H/W_OT-  H/W OT- 
Under the standard specifications, the OT (-) signal is 
assigned to a fixed device.  When it is desired to assign 
the OT (-) g signal to a position other than the fixed 
device, specify the input device in this parameter. 
Note 1:  This parameter is valid when 1 is set in #1226 
aux10 bit 5. 
Note 2:  When this parameter is valid, do not set the 
same device number.  If the same device 
number exists, an emergency stop occurs.  
However, no device number check is performed 
for an axis to which a signal that ignores the OT 
signal (R156) is input. 
00 to FF (HEX) 
2076 index_x 
Index 
table 
indexing 
axis 
Specify the index table indexing axis. 
0:  Normal axis 
1:  Index table indexing axis 
Note:  This parameter is valid only for the NC axis.  The 
parameter is invalid if specified for the PLC axis. 
0/1 
2077 G0inps 
G0 
in-position 
width 
When an in-position check is performed for G0, this 
parameter is valid. 
(Comparison of SV024 and this parameter, the 
parameter that the in-position width is wider is applied.) 
When 0 is set, this parameter is invalid. 
(Applicable only to SV024) 
0 to 32767 (
µm)