Справочник Пользователя для Mitsubishi Electronics E60

Скачать
Страница из 415
6. 
AXIS SPECIFICATIONS PARAMETERS 
6.4 
Axis Specifications Parameters 2 
II - 94 
6.4  Axis Specifications Parameters 2 
(SETUP PARAM 2. 6/8) 
Items 
Details 
Setting range (unit) 
2061  0T
_1B−  Soft limit IB−  Set up the coordinates of the lower limit of the inhibited 
area of stored stroke limit IB. 
Specify a value in the basic mechanical coordinates 
system.  If the same value (non-zero) with the same 
sign as that of #2062 0T_IB+ is specified, the stored 
stroke limit IB function is disabled. 
±99999.999 (mm) 
2062  0T
_1B+  Soft limit IB+  Set up the coordinates of the upper limit of the inhibited 
area of stored stroke limit IB. 
Specify a value in the basic mechanical coordinates 
system. 
±99999.999 (mm) 
2063  0T
_1B 
type 
Soft limit IB 
type 
Select 0T_IB or 0T_IC in which 0T_IB+/
− is used in 
stored stroke limit I. 
0:  Soft limit IB valid 
1:  Soft limit IB invalid 
2:  Soft limit IC valid 
3:  When using the inclined axis specifications, the 
soft limit is checked with the program coordinate 
system. 
Note:  This is invalid for axes other than the 
inclined axis' base axis and inclined 
axis. 
0/1/2/3 
2064  
 
Not used. 
 
2065  
 
Not used. 
 
2066  
 
Not used. 
 
2067  
 
Not used.